This drawing shows alternate types of curb that may be used on curb and gutter combined.
Curb and gutter type 3 ohio.
133 kb roadway design features roadway miscellaneous.
Concrete curbs and combined curb gutter.
Any section or portion of a section of curb thereof whose edges differ vertically by more than 1 from the adjoining sections or portion of a section of curb or any sidewalk or driveway approach that adjoins such curb.
Sidewalks stores parking spaces etc.
Barrier curbs are typically comprised of asphalt aggregates or cement concrete.
Lateral contraction joints shall be placed at intervals of not more than 15 nor less than 6 in length.
1 expansion joints shall extend up to the top of the curb and edge of the curb and gutter section.
Concrete shall be cement concrete class c.
Notes type b ribbon curb notes vertical curb gutter with depressed lip type a 2.
340 729 and cos sec.
Completely sever the structure to the points shown.
7 seeding and mulching item 659.
Type to be used also the thickness of the edge of the pavement or the various types of pavement.
Sht 3 of 7 1441 city of columbus ohio department of public service division of design and construction 12 1 13.
Type ra valley gutter concrete curb concrete curb and gutter roundabout central island construction traffic bearing section for use in a a b b c c valley gutter curb and gutter 1 10 1 2 1 10 1 2 r 3 4 1 r 4 3 4 1 6 3 0 2 7 6 m i n s t d.
Criteria for condemning curb gutter 1.
4 compacted subgrade item 203 13.
3 six inch base course of item 301 bituminous aggregate base.
This is the most commonly used curb all over the globe.
Contraction joint spacing shall be 10 maximum.
Single slope barrier types b c b1 c1.
Ohio manual of uniform traffic control devices omutcd revisions updates.
Piece asphaltic material having the same dimensions as curb gutter at that station and be 1 2 thick.
2020 combination curb gutter type special 8 06 01 2014 2030 combination curb gutter type mountable 06 01 2013 2100 26 section residential combination curb gutter type.
2 1 7 6 m i n s t d.
Contraction joints of one of these types shown above to be placed 1 o c c.
Contraction joint spacing shall be 10 maximum or as directed by the inspector.
Any section of curb having crack or cracks in it more than wide.
The typical section of the project shows the general.
1 7 rr 3 4 4 1 6 2 1 7 5 0 8 6 1 0.
Joints may be made by inserting min.
As the name denotes this type of curb is used as a barrier between vehicles and certain spaces e g.
Construct curb and install mastic1 2 expansion joints a s t m.
Joints shall be cleaned and edged.
6 four inch thick class c concrete sidewalk five feet wide item 608.
5 roll type curb and gutter item 609 butler county standard c 1.