The taller it is the more of a tendency it has to turn over when a lateral force is applied.
Do i need to shear wall for siding.
It s best to stagger the joints in each successive course to avoid noticeable patterns.
In order to be effective tall skinny shearwalls either need to grow in width or the connections between the sheathing and framing members need to be increased.
This guide is available as a free download from the apa.
Even if you never have a storm or an earthquake or otherwise any need for the shear stregnth of your exterior walls somewhere sometime someone s gonna throw a baseball at your garage and it s gonna punch a nice hole in your nice hardi siding.
Siding shear walls 2306 3 wood structural panel shear walls.
Their job is to keep the inside in and the outside out.
The walls of your home are an environmental separator.
To account for this overage in material find the square footage of space that will not be covered in siding for the doors and windows and subtract that from the total square footage of the wall.
For example an average door is 3ft wide by 7ft.
Framing or one bay for 24 inch o c.
I want to frame sheathe a wall with cdx install felt and windows and doors and then install siding or preferably sidewall shingles.
I m set in my ways.
Need to combine with top floor hold down requirements based on capacity of first shear wall panel does not include dead load.
2 on the ends if there is a double stud for a hold down you can either stitch nail the two studs together 3 o c.
The.
And stagger nails 6 o c.
Is t 111 siding considered structural.
You can go over preexisting siding as long as it is flat and in good shape.
Finally as for shear stregnth i can rip a hardi panel w my bare hands.
Exterior cladding or siding is your first line of defense against weather elements and its job is to allow interior control layers ie.
Right but to make it into shear i d have to nail the sh t out of it with big headed nails rather than the slight head spirals that i use with t1 11.
The building envelope to do their jobs without being assaulted by wind precipitation and uv rays.
On each stud this makes a total of 3 o c.
A wall with doors and windows may require less squares of material to cover than a wall with no doors.
Butt joints in adjacent courses should be spaced apart by at least two stud bays for 16 inch o c.
Remember your shear wall may be the only thing between safety and catastrophe and it needs to be built perfectly.
Nailing on this edge or nail into the.
Remove and repair any damage portions and use a weather restrictive barrier between our product and the preexisting siding.